<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://projectswiki.eleceng.adelaide.edu.au/projects/index.php?action=history&amp;feed=atom&amp;title=Projects%3A2020s1-2511_Small-Scale_Torque_Gauge</id>
	<title>Projects:2020s1-2511 Small-Scale Torque Gauge - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://projectswiki.eleceng.adelaide.edu.au/projects/index.php?action=history&amp;feed=atom&amp;title=Projects%3A2020s1-2511_Small-Scale_Torque_Gauge"/>
	<link rel="alternate" type="text/html" href="https://projectswiki.eleceng.adelaide.edu.au/projects/index.php?title=Projects:2020s1-2511_Small-Scale_Torque_Gauge&amp;action=history"/>
	<updated>2026-06-29T08:02:24Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.31.4</generator>
	<entry>
		<id>https://projectswiki.eleceng.adelaide.edu.au/projects/index.php?title=Projects:2020s1-2511_Small-Scale_Torque_Gauge&amp;diff=15208&amp;oldid=prev</id>
		<title>A1753084 at 02:22, 11 October 2020</title>
		<link rel="alternate" type="text/html" href="https://projectswiki.eleceng.adelaide.edu.au/projects/index.php?title=Projects:2020s1-2511_Small-Scale_Torque_Gauge&amp;diff=15208&amp;oldid=prev"/>
		<updated>2020-10-11T02:22:03Z</updated>

		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table class=&quot;diff diff-contentalign-left&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #222; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #222; text-align: center;&quot;&gt;Revision as of 02:22, 11 October 2020&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l28&quot; &gt;Line 28:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 28:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The strain gauge load cell is constructed to find the small changes in resistance more accurately. It uses the Wheatstone bridge principle to measure the output voltage by detecting the sensed force through the deformation of multiple strain gauges. Replacing the resistors in Wheatstone bridge to strain gauges, the magnitude of the force applied on the object will change the magnitude of the resistance, thereby changing the output voltage. Only replace one resistor to strain gauge in Wheatstone bridge is called Quarter-bridge circuit. When using the Quarter-bridge circuit in actual operation, the accuracy of the measurement is greatly affected by temperature and wire resistance. Half-bridge circuit, which replaces two resistors to strain gauges, can reduce the influence of these two factors and make the circuit more responsive to the applied force. Because the wires connected between two strain gauges and circuit have equal length and the effects of wires tend to be cancelled. On the other hand, the effects of temperature change also cancelled since both strain gauges will either increase or decrease resistance by the same proportion in response to changes in temperature [3]. Another way is replacing all resistors in Wheatstone bridge to strain gauges, and it is called full-bridge circuit. It is more sensitive than half-bridge circuit, but the circuit may be more challenging to build in practical.&lt;/div&gt;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The strain gauge load cell is constructed to find the small changes in resistance more accurately. It uses the Wheatstone bridge principle to measure the output voltage by detecting the sensed force through the deformation of multiple strain gauges. Replacing the resistors in Wheatstone bridge to strain gauges, the magnitude of the force applied on the object will change the magnitude of the resistance, thereby changing the output voltage. Only replace one resistor to strain gauge in Wheatstone bridge is called Quarter-bridge circuit. When using the Quarter-bridge circuit in actual operation, the accuracy of the measurement is greatly affected by temperature and wire resistance. Half-bridge circuit, which replaces two resistors to strain gauges, can reduce the influence of these two factors and make the circuit more responsive to the applied force. Because the wires connected between two strain gauges and circuit have equal length and the effects of wires tend to be cancelled. On the other hand, the effects of temperature change also cancelled since both strain gauges will either increase or decrease resistance by the same proportion in response to changes in temperature [3]. Another way is replacing all resistors in Wheatstone bridge to strain gauges, and it is called full-bridge circuit. It is more sensitive than half-bridge circuit, but the circuit may be more challenging to build in practical.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&#039;diff-marker&#039;&gt;−&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==== Instrumentation Amplifier ====&lt;/div&gt;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==== Instrumentation Amplifier ==== &amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&#039;diff-marker&#039;&gt;−&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Since the change of resistance may be very small in the strain gauge load cell, the output voltage may be tiny and not easy to measure. [[File:Amplifier &lt;del class=&quot;diffchange diffchange-inline&quot;&gt;Design&lt;/del&gt;.png|thumb&lt;del class=&quot;diffchange diffchange-inline&quot;&gt;|caption&lt;/del&gt;]]The circuit needs to add an instrumentation amplifier to amplify the output voltage for more convenient measurement. The instrumentation amplifier is a type of differential amplifier that has been outfitted with input buffer amplifiers. It consists of a buffered differential amplifier stage with two buffer circuits linked together by three resistors. All resistors have equal value except R_gain. The gain of the circuit is [[File:Formula 2.png|thumb]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Since the change of resistance may be very small in the strain gauge load cell, the output voltage may be tiny and not easy to measure. [[File:&lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;Instrumentation &lt;/ins&gt;Amplifier &lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;Circuit&lt;/ins&gt;.png|thumb]]The circuit needs to add an instrumentation amplifier to amplify the output voltage for more convenient measurement. The instrumentation amplifier is a type of differential amplifier that has been outfitted with input buffer amplifiers. It consists of a buffered differential amplifier stage with two buffer circuits linked together by three resistors. All resistors have equal value except R_gain. The gain of the circuit is [[File:Formula 2.png|thumb]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&#039;diff-marker&#039;&gt;−&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del class=&quot;diffchange diffchange-inline&quot;&gt;=&lt;/del&gt;== Methodology &lt;del class=&quot;diffchange diffchange-inline&quot;&gt;=&lt;/del&gt;==&lt;/div&gt;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Methodology ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Changing two resistors in Wheatstone bridge to strain gauges. When the motor turn on, two strain gauges would be compressed and another two would be stretched. Measure the output voltage can find the value of torque. [[File:Circuit design.png|frameless|caption]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Changing two resistors in Wheatstone bridge to strain gauges. When the motor turn on, two strain gauges would be compressed and another two would be stretched. Measure the output voltage can find the value of torque. [[File:Circuit design.png|frameless|caption]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;== OutComes ==&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;There is an approximately linear relationship between torque and output voltage values. The torque can be calculated by measuring the output voltage of circuit. &lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:3D Structure.png|frameless]]&amp;#160; &amp;#160; &amp;#160; &amp;#160; &amp;#160; &amp;#160; &amp;#160; &amp;#160; &amp;#160; &amp;#160; [[File:Outcome circuit.png|frameless]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;== Future Works ==&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;1. Improve the circuit to make the measurement more accurate.&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;2. Adjust the size of the prototype so that the gauge can measure motors of different sizes.&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;== Reference ==&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[1] A. C. Ugural, Mechanics of Materials, McGraw-Hill Book Co, 1991, pp. 130-134.&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[2] W.J. Bock, R. Wisniewski, T.R. Wolinski, IEEE Transactions on Instrumentation and Measurement, vol.41, pp. 72-76, 1992.&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>A1753084</name></author>
		
	</entry>
	<entry>
		<id>https://projectswiki.eleceng.adelaide.edu.au/projects/index.php?title=Projects:2020s1-2511_Small-Scale_Torque_Gauge&amp;diff=15194&amp;oldid=prev</id>
		<title>A1753084 at 04:28, 10 October 2020</title>
		<link rel="alternate" type="text/html" href="https://projectswiki.eleceng.adelaide.edu.au/projects/index.php?title=Projects:2020s1-2511_Small-Scale_Torque_Gauge&amp;diff=15194&amp;oldid=prev"/>
		<updated>2020-10-10T04:28:48Z</updated>

		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table class=&quot;diff diff-contentalign-left&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #222; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #222; text-align: center;&quot;&gt;Revision as of 04:28, 10 October 2020&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l21&quot; &gt;Line 21:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 21:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==== Strain Gauge ====&lt;/div&gt;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==== Strain Gauge ====&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&#039;diff-marker&#039;&gt;−&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The strain gauge is the essential component of small-scale torque gauge. It is a device used to measure the strain on an object or stresses generated by[[File:Wire Lead Strain Gauge 4mm.png|thumb&lt;del class=&quot;diffchange diffchange-inline&quot;&gt;|caption&lt;/del&gt;]] machinery. The general strain gauge consists of insulating flexible backing, which embeds different size metallic foil pattern [1]. A strain gauge takes advantage of the physical property of electrical conductance. Metallic foil would deform as the object deforms, causing the change of strain gauge electrical resistance. When measuring, ensure that the gauge is stretched or compressed within the limits of its elasticity without breaking or permanent deformation. When the gauge is stretched, the metallic foil will become longer and thinner and increase the strain gauge&amp;#039;s electrical resistance. On the contrary, when the gauge is compressed, the metallic foil will become shorten and broaden and decrease the electrical resistance of strain gauge [2]. By accurately measuring the change of strain gauge resistance, the magnitude of the induced force on the object can be inferred. &amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The strain gauge is the essential component of small-scale torque gauge. It is a device used to measure the strain on an object or stresses generated by[[File:Wire Lead Strain Gauge 4mm.png|thumb]] machinery. The general strain gauge consists of insulating flexible backing, which embeds different size metallic foil pattern [1]. A strain gauge takes advantage of the physical property of electrical conductance. Metallic foil would deform as the object deforms, causing the change of strain gauge electrical resistance. When measuring, ensure that the gauge is stretched or compressed within the limits of its elasticity without breaking or permanent deformation. When the gauge is stretched, the metallic foil will become longer and thinner and increase the strain gauge&amp;#039;s electrical resistance. On the contrary, when the gauge is compressed, the metallic foil will become shorten and broaden and decrease the electrical resistance of strain gauge [2]. By accurately measuring the change of strain gauge resistance, the magnitude of the induced force on the object can be inferred. &amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The resistance of a standard strain gauge ranges from 30Ω to 3000Ω. When measuring under the elastic limit of the given gauge material, the resistance of strain gauge may change only one percent. If more force is applied to cause a more significant resistance change, it may cause permanent deformation of the metallic foil and damage the strain gauge. Thus, in order to apply gauge to actual measurement, it is necessary to measure extremely small changes in resistance with high accuracy.&lt;/div&gt;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The resistance of a standard strain gauge ranges from 30Ω to 3000Ω. When measuring under the elastic limit of the given gauge material, the resistance of strain gauge may change only one percent. If more force is applied to cause a more significant resistance change, it may cause permanent deformation of the metallic foil and damage the strain gauge. Thus, in order to apply gauge to actual measurement, it is necessary to measure extremely small changes in resistance with high accuracy.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>A1753084</name></author>
		
	</entry>
	<entry>
		<id>https://projectswiki.eleceng.adelaide.edu.au/projects/index.php?title=Projects:2020s1-2511_Small-Scale_Torque_Gauge&amp;diff=15192&amp;oldid=prev</id>
		<title>A1753084 at 07:47, 3 October 2020</title>
		<link rel="alternate" type="text/html" href="https://projectswiki.eleceng.adelaide.edu.au/projects/index.php?title=Projects:2020s1-2511_Small-Scale_Torque_Gauge&amp;diff=15192&amp;oldid=prev"/>
		<updated>2020-10-03T07:47:34Z</updated>

		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table class=&quot;diff diff-contentalign-left&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #222; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #222; text-align: center;&quot;&gt;Revision as of 07:47, 3 October 2020&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l26&quot; &gt;Line 26:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 26:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==== Load Cell ====&lt;/div&gt;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==== Load Cell ====&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The Wheatstone bridge circuit is using two series-parallel arrangements of resistances connected between a voltage supply terminal and ground producing zero voltage difference between the two parallel branches when balanced. The output voltage can be calculated by formula: [[File:Formula.png|thumb]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The Wheatstone bridge circuit is using two series-parallel arrangements of resistances connected between a voltage supply terminal and ground producing zero voltage difference between the two parallel branches when balanced. The output voltage can be calculated by formula: [[File:Formula.png|thumb]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;The strain gauge load cell is constructed to find the small changes in resistance more accurately. It uses the Wheatstone bridge principle to measure the output voltage by detecting the sensed force through the deformation of multiple strain gauges. Replacing the resistors in Wheatstone bridge to strain gauges, the magnitude of the force applied on the object will change the magnitude of the resistance, thereby changing the output voltage. Only replace one resistor to strain gauge in Wheatstone bridge is called Quarter-bridge circuit. When using the Quarter-bridge circuit in actual operation, the accuracy of the measurement is greatly affected by temperature and wire resistance. Half-bridge circuit, which replaces two resistors to strain gauges, can reduce the influence of these two factors and make the circuit more responsive to the applied force. Because the wires connected between two strain gauges and circuit have equal length and the effects of wires tend to be cancelled. On the other hand, the effects of temperature change also cancelled since both strain gauges will either increase or decrease resistance by the same proportion in response to changes in temperature [3]. Another way is replacing all resistors in Wheatstone bridge to strain gauges, and it is called full-bridge circuit. It is more sensitive than half-bridge circuit, but the circuit may be more challenging to build in practical.&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;==== Instrumentation Amplifier ====&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Since the change of resistance may be very small in the strain gauge load cell, the output voltage may be tiny and not easy to measure. [[File:Amplifier Design.png|thumb|caption]]The circuit needs to add an instrumentation amplifier to amplify the output voltage for more convenient measurement. The instrumentation amplifier is a type of differential amplifier that has been outfitted with input buffer amplifiers. It consists of a buffered differential amplifier stage with two buffer circuits linked together by three resistors. All resistors have equal value except R_gain. The gain of the circuit is [[File:Formula 2.png|thumb]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;=== Methodology ===&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Changing two resistors in Wheatstone bridge to strain gauges. When the motor turn on, two strain gauges would be compressed and another two would be stretched. Measure the output voltage can find the value of torque. [[File:Circuit design.png|frameless|caption]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>A1753084</name></author>
		
	</entry>
	<entry>
		<id>https://projectswiki.eleceng.adelaide.edu.au/projects/index.php?title=Projects:2020s1-2511_Small-Scale_Torque_Gauge&amp;diff=15188&amp;oldid=prev</id>
		<title>A1753084 at 07:32, 3 October 2020</title>
		<link rel="alternate" type="text/html" href="https://projectswiki.eleceng.adelaide.edu.au/projects/index.php?title=Projects:2020s1-2511_Small-Scale_Torque_Gauge&amp;diff=15188&amp;oldid=prev"/>
		<updated>2020-10-03T07:32:56Z</updated>

		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table class=&quot;diff diff-contentalign-left&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #222; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #222; text-align: center;&quot;&gt;Revision as of 07:32, 3 October 2020&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l25&quot; &gt;Line 25:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 25:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==== Load Cell ====&lt;/div&gt;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==== Load Cell ====&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&#039;diff-marker&#039;&gt;−&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The Wheatstone bridge circuit is using two series-parallel arrangements of resistances connected between a voltage supply terminal and ground producing zero voltage difference between the two parallel branches when balanced. The output voltage can be calculated by formula:&lt;/div&gt;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The Wheatstone bridge circuit is using two series-parallel arrangements of resistances connected between a voltage supply terminal and ground producing zero voltage difference between the two parallel branches when balanced. The output voltage can be calculated by formula: &lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;[[File:Formula.png|thumb]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>A1753084</name></author>
		
	</entry>
	<entry>
		<id>https://projectswiki.eleceng.adelaide.edu.au/projects/index.php?title=Projects:2020s1-2511_Small-Scale_Torque_Gauge&amp;diff=15186&amp;oldid=prev</id>
		<title>A1753084 at 07:29, 3 October 2020</title>
		<link rel="alternate" type="text/html" href="https://projectswiki.eleceng.adelaide.edu.au/projects/index.php?title=Projects:2020s1-2511_Small-Scale_Torque_Gauge&amp;diff=15186&amp;oldid=prev"/>
		<updated>2020-10-03T07:29:25Z</updated>

		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table class=&quot;diff diff-contentalign-left&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #222; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #222; text-align: center;&quot;&gt;Revision as of 07:29, 3 October 2020&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l23&quot; &gt;Line 23:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 23:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The strain gauge is the essential component of small-scale torque gauge. It is a device used to measure the strain on an object or stresses generated by[[File:Wire Lead Strain Gauge 4mm.png|thumb|caption]] machinery. The general strain gauge consists of insulating flexible backing, which embeds different size metallic foil pattern [1]. A strain gauge takes advantage of the physical property of electrical conductance. Metallic foil would deform as the object deforms, causing the change of strain gauge electrical resistance. When measuring, ensure that the gauge is stretched or compressed within the limits of its elasticity without breaking or permanent deformation. When the gauge is stretched, the metallic foil will become longer and thinner and increase the strain gauge&amp;#039;s electrical resistance. On the contrary, when the gauge is compressed, the metallic foil will become shorten and broaden and decrease the electrical resistance of strain gauge [2]. By accurately measuring the change of strain gauge resistance, the magnitude of the induced force on the object can be inferred. &amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The strain gauge is the essential component of small-scale torque gauge. It is a device used to measure the strain on an object or stresses generated by[[File:Wire Lead Strain Gauge 4mm.png|thumb|caption]] machinery. The general strain gauge consists of insulating flexible backing, which embeds different size metallic foil pattern [1]. A strain gauge takes advantage of the physical property of electrical conductance. Metallic foil would deform as the object deforms, causing the change of strain gauge electrical resistance. When measuring, ensure that the gauge is stretched or compressed within the limits of its elasticity without breaking or permanent deformation. When the gauge is stretched, the metallic foil will become longer and thinner and increase the strain gauge&amp;#039;s electrical resistance. On the contrary, when the gauge is compressed, the metallic foil will become shorten and broaden and decrease the electrical resistance of strain gauge [2]. By accurately measuring the change of strain gauge resistance, the magnitude of the induced force on the object can be inferred. &amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The resistance of a standard strain gauge ranges from 30Ω to 3000Ω. When measuring under the elastic limit of the given gauge material, the resistance of strain gauge may change only one percent. If more force is applied to cause a more significant resistance change, it may cause permanent deformation of the metallic foil and damage the strain gauge. Thus, in order to apply gauge to actual measurement, it is necessary to measure extremely small changes in resistance with high accuracy.&lt;/div&gt;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The resistance of a standard strain gauge ranges from 30Ω to 3000Ω. When measuring under the elastic limit of the given gauge material, the resistance of strain gauge may change only one percent. If more force is applied to cause a more significant resistance change, it may cause permanent deformation of the metallic foil and damage the strain gauge. Thus, in order to apply gauge to actual measurement, it is necessary to measure extremely small changes in resistance with high accuracy.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;==== Load Cell ====&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;The Wheatstone bridge circuit is using two series-parallel arrangements of resistances connected between a voltage supply terminal and ground producing zero voltage difference between the two parallel branches when balanced. The output voltage can be calculated by formula:&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>A1753084</name></author>
		
	</entry>
	<entry>
		<id>https://projectswiki.eleceng.adelaide.edu.au/projects/index.php?title=Projects:2020s1-2511_Small-Scale_Torque_Gauge&amp;diff=15185&amp;oldid=prev</id>
		<title>A1753084: /* Strain Gauge */</title>
		<link rel="alternate" type="text/html" href="https://projectswiki.eleceng.adelaide.edu.au/projects/index.php?title=Projects:2020s1-2511_Small-Scale_Torque_Gauge&amp;diff=15185&amp;oldid=prev"/>
		<updated>2020-10-03T07:05:48Z</updated>

		<summary type="html">&lt;p&gt;‎&lt;span dir=&quot;auto&quot;&gt;&lt;span class=&quot;autocomment&quot;&gt;Strain Gauge&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;table class=&quot;diff diff-contentalign-left&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #222; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #222; text-align: center;&quot;&gt;Revision as of 07:05, 3 October 2020&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l21&quot; &gt;Line 21:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 21:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==== Strain Gauge ====&lt;/div&gt;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==== Strain Gauge ====&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&#039;diff-marker&#039;&gt;−&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The strain gauge is the essential component of small-scale torque gauge. It is a device used to measure the strain on an object or stresses generated by machinery. The general strain gauge consists of insulating flexible backing, which embeds different size metallic foil pattern [&lt;del class=&quot;diffchange diffchange-inline&quot;&gt;2&lt;/del&gt;]. A strain gauge takes advantage of the physical property of electrical conductance. Metallic foil would deform as the object deforms, causing the change of strain gauge electrical resistance. When measuring, ensure that the gauge is stretched or compressed within the limits of its elasticity without breaking or permanent deformation. When the gauge is stretched, the metallic foil will become longer and thinner and increase the strain gauge&amp;#039;s electrical resistance. On the contrary, when the gauge is compressed, the metallic foil will become shorten and broaden and decrease the electrical resistance of strain gauge [&lt;del class=&quot;diffchange diffchange-inline&quot;&gt;3&lt;/del&gt;]. By accurately measuring the change of strain gauge resistance, the magnitude of the induced force on the object can be inferred. &amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The strain gauge is the essential component of small-scale torque gauge. It is a device used to measure the strain on an object or stresses generated by&lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;[[File:Wire Lead Strain Gauge 4mm.png|thumb|caption]] &lt;/ins&gt;machinery. The general strain gauge consists of insulating flexible backing, which embeds different size metallic foil pattern [&lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;1&lt;/ins&gt;]. A strain gauge takes advantage of the physical property of electrical conductance. Metallic foil would deform as the object deforms, causing the change of strain gauge electrical resistance. When measuring, ensure that the gauge is stretched or compressed within the limits of its elasticity without breaking or permanent deformation. When the gauge is stretched, the metallic foil will become longer and thinner and increase the strain gauge&amp;#039;s electrical resistance. On the contrary, when the gauge is compressed, the metallic foil will become shorten and broaden and decrease the electrical resistance of strain gauge [&lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;2&lt;/ins&gt;]. By accurately measuring the change of strain gauge resistance, the magnitude of the induced force on the object can be inferred. &amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The resistance of a standard strain gauge ranges from 30Ω to 3000Ω. When measuring under the elastic limit of the given gauge material, the resistance of strain gauge may change only one percent. If more force is applied to cause a more significant resistance change, it may cause permanent deformation of the metallic foil and damage the strain gauge. Thus, in order to apply gauge to actual measurement, it is necessary to measure extremely small changes in resistance with high accuracy.&lt;/div&gt;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The resistance of a standard strain gauge ranges from 30Ω to 3000Ω. When measuring under the elastic limit of the given gauge material, the resistance of strain gauge may change only one percent. If more force is applied to cause a more significant resistance change, it may cause permanent deformation of the metallic foil and damage the strain gauge. Thus, in order to apply gauge to actual measurement, it is necessary to measure extremely small changes in resistance with high accuracy.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&#039;diff-marker&#039;&gt;−&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:Wire Lead Strain Gauge 4mm.png|thumb]]&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>A1753084</name></author>
		
	</entry>
	<entry>
		<id>https://projectswiki.eleceng.adelaide.edu.au/projects/index.php?title=Projects:2020s1-2511_Small-Scale_Torque_Gauge&amp;diff=15184&amp;oldid=prev</id>
		<title>A1753084 at 06:59, 3 October 2020</title>
		<link rel="alternate" type="text/html" href="https://projectswiki.eleceng.adelaide.edu.au/projects/index.php?title=Projects:2020s1-2511_Small-Scale_Torque_Gauge&amp;diff=15184&amp;oldid=prev"/>
		<updated>2020-10-03T06:59:21Z</updated>

		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table class=&quot;diff diff-contentalign-left&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #222; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #222; text-align: center;&quot;&gt;Revision as of 06:59, 3 October 2020&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l13&quot; &gt;Line 13:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 13:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*Bohan Liu&lt;/div&gt;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*Bohan Liu&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*Weixi Tao&lt;/div&gt;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*Weixi Tao&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;== Background ==&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;This project aims to construct a small-scale torque gauge that is based on a spaceframe (3D-truss) together with commercially available strain gauges. Strain gauge that converts applied force or torque into a change in electrical resistance. Using strain gauges to build a strain gauge load cell to measure the torque. That has a lower cost and can be used in small desktop projects. The initial test of concept would involve the measurement of a three-phase permanent magnet machine over a range of operating conditions. In principle, this apparatus could measure dynamic time-dependent torque, as well as steady-state torque. Besides, the torque gauge could be used to measure a range of different machines for future projects and can be used as a teaching aid demonstration in the experimental class.&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;=== Technical Background ===&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;==== Strain Gauge ====&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;The strain gauge is the essential component of small-scale torque gauge. It is a device used to measure the strain on an object or stresses generated by machinery. The general strain gauge consists of insulating flexible backing, which embeds different size metallic foil pattern [2]. A strain gauge takes advantage of the physical property of electrical conductance. Metallic foil would deform as the object deforms, causing the change of strain gauge electrical resistance. When measuring, ensure that the gauge is stretched or compressed within the limits of its elasticity without breaking or permanent deformation. When the gauge is stretched, the metallic foil will become longer and thinner and increase the strain gauge&amp;#039;s electrical resistance. On the contrary, when the gauge is compressed, the metallic foil will become shorten and broaden and decrease the electrical resistance of strain gauge [3]. By accurately measuring the change of strain gauge resistance, the magnitude of the induced force on the object can be inferred. &lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;The resistance of a standard strain gauge ranges from 30Ω to 3000Ω. When measuring under the elastic limit of the given gauge material, the resistance of strain gauge may change only one percent. If more force is applied to cause a more significant resistance change, it may cause permanent deformation of the metallic foil and damage the strain gauge. Thus, in order to apply gauge to actual measurement, it is necessary to measure extremely small changes in resistance with high accuracy.&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class=&#039;diff-marker&#039;&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:Wire Lead Strain Gauge 4mm.png|thumb]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>A1753084</name></author>
		
	</entry>
	<entry>
		<id>https://projectswiki.eleceng.adelaide.edu.au/projects/index.php?title=Projects:2020s1-2511_Small-Scale_Torque_Gauge&amp;diff=13974&amp;oldid=prev</id>
		<title>A1753084: Created page with &quot;== Introduction ==  In order to estimate mechanical power delivered by a rotating machine, it is necessary to measure two variables, torque (T) and angular velocity (omega). A...&quot;</title>
		<link rel="alternate" type="text/html" href="https://projectswiki.eleceng.adelaide.edu.au/projects/index.php?title=Projects:2020s1-2511_Small-Scale_Torque_Gauge&amp;diff=13974&amp;oldid=prev"/>
		<updated>2020-04-05T04:25:57Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;== Introduction ==  In order to estimate mechanical power delivered by a rotating machine, it is necessary to measure two variables, torque (T) and angular velocity (omega). A...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;== Introduction ==&lt;br /&gt;
&lt;br /&gt;
In order to estimate mechanical power delivered by a rotating machine, it is necessary to measure two variables, torque (T) and angular velocity (omega). Angular velocity is typically measured using an encoding wheel. Commercial torque gauges are typically very expensive and operate over a range that is too large for small desktop projects. In this project, we will construct a small torque gauge that is based on a spaceframe (3D-truss) together with commercially available strain gauges.&lt;br /&gt;
&lt;br /&gt;
== Project Team ==&lt;br /&gt;
&lt;br /&gt;
=== Supervisors ===&lt;br /&gt;
&lt;br /&gt;
*Dr. Andrew Allison&lt;br /&gt;
*Dr. Derek Abbott&lt;br /&gt;
&lt;br /&gt;
=== Students ===&lt;br /&gt;
*Bohan Liu&lt;br /&gt;
*Weixi Tao&lt;/div&gt;</summary>
		<author><name>A1753084</name></author>
		
	</entry>
</feed>