− | Student name: | + | == supervisors == |
+ | |||
+ | Dr. Andrew Alison | ||
+ | Dr. Rastko Zivanovic | ||
+ | |||
+ | == Student name: == | ||
+ | |||
+ | |||
+ | |||
Chen Qiao | Chen Qiao | ||
Rahel Bekele Megersa | Rahel Bekele Megersa | ||
+ | |||
+ | == summary == | ||
+ | |||
+ | This report is a part of continuing project. The aim of this project is to create a semi-automated method for estimating of the transformer parameters. In this project we use self-resonant frequency to get the best frequency. In addition, we use 1-port device and 2-port device. In order to test some of our calculations, we will disassemble some transformers. We can obtain absolute measurements of the numbers of turns, and core-dimensions. Obviously, we will combine a variety of measurements, with some mathematical methods, to estimate the parameters of transformers. One important method is, Least Square Spectral Analysis (LSSA). If the transformer is operating in a non-linear mode, under conditions of high current, for example the resulting distortion will produce higher-order components in the Fourier series, which can be estimated using a modification of the LSSA method. Previous work has shown that Transmission-Parameters lead to a simple formulation of our problem. |
Latest revision as of 12:51, 25 October 2016
Measurement of transformer parameters
supervisors
Dr. Andrew Alison Dr. Rastko Zivanovic
Student name:
Chen Qiao Rahel Bekele Megersa
summary
This report is a part of continuing project. The aim of this project is to create a semi-automated method for estimating of the transformer parameters. In this project we use self-resonant frequency to get the best frequency. In addition, we use 1-port device and 2-port device. In order to test some of our calculations, we will disassemble some transformers. We can obtain absolute measurements of the numbers of turns, and core-dimensions. Obviously, we will combine a variety of measurements, with some mathematical methods, to estimate the parameters of transformers. One important method is, Least Square Spectral Analysis (LSSA). If the transformer is operating in a non-linear mode, under conditions of high current, for example the resulting distortion will produce higher-order components in the Fourier series, which can be estimated using a modification of the LSSA method. Previous work has shown that Transmission-Parameters lead to a simple formulation of our problem.