General info

Supervisors Info

Team members

Asmita Dumur

Bo Zhou

Pengchao Yang

Introduction

Topic

  • Transferring 5W with over 80% efficiency at given distance of 500 mm between transmitter and receiver coils
  • Design of a charging surface of a standard desk, which is able to transfer 2W at least 60% efficiency

Motivation

The mainstream of power delivery, nowadays, is to advance the wireless power transmission technique. Wireless charging technology is a major theme at Mobile World Congress (MWC) in 2015. From the commercial perspective, an innovative, advanced and efficient product means more profits for manufacturers. Some well-known companies have invested in development of a better charging technique, such as Apple and Samsung. Therefore, one reason for conducting this project is that it is probably a well-paid task, and meanwhile is closely related to the current investigating trend in the technical field of power transfer. Apart from the commercial view, a main reason can be found at users’ perspective. The wireless charging system produced by this project might offer users an impressive experience. General speaking, convenience shall be primarily presented. Firstly, there are two limitations on current wireless charging products. Some light products can only charge a single device at a time. Or some cumbersome chargers can charge multi-devices at a time but they require users to place all devices on a charging pad [6]. In the project, overcoming above drawbacks should be taken into account while designing a product. Additionally, the wireless charging system is able to be a uniform charger for all different devices charging. Technically, it allows the minimum of the charging cable use [7]. Furthermore, using the system would not be limited in some particular environment. Devices can be charged even under very dirty surroundings via the wireless charging system.

Technology Background

Methods used in inductive power transfer (IPT) field

At the present there are three approaches that are able to transfer energy without using any cables. They are Microwaves, Magnetic Resonance and Laser methods [5]. These three different ways have their own features and advantages. For instance, the Microwave method is always applied in long distance electric power transmission. However, it has to apply the high frequency ranging from 1GHz to 1000 GHz, which could cause some injurious for health. Regarding to the Laser method, it can be selected to some long and small distance applications, which is flexible. Nevertheless, it also causes some health issues. The last one is the magnetic resonance method. From biological views, it is a safe way to human bodies. In the project this method is a key approach.

Magnetic resonance method

The magnetic resonance method involves the coupling of two or more coils: “ when coupled a current in one coil causes an induced voltage in the other hence under the correct conditions that voltage can be used to power some application and in these circumstances power is transferred by induction from one coil to another without physical contact.”[2]. The key requirement of this method is that the coupled coils need to operate at the resonance condition. The reasons of applying this method are able to be concluded in three points. At the beginning, the method can offer possibility of power transfers with high efficiency. For instance, for a given distance of 400mm between transmitter and receiver coils, operating at 100kHz to transfer 1kW, the complete system achieved an total efficiency >80%, which includes all the power electronics [2]. Moreover, at the view of costs for build the system, the method undoubtedly minimises the costs. It has been pointed out that the method is economical as the equipment used is cheap and easily available [5]. Ultimately, the method would be limited by environment. Covic [2] comments that such power transmission is clean and it can not be impacted by chemicals or dirt.

Equivelant circuit

Equivelant Circuit.png

Efficiency that is being investigated and explored in the project refers to the quality of energy transmission between two coils. The discussion of the efficiency is always associated with a two-coil-circuit, which has been illustrated in Figure 3.1. There are six combinations in total and each of them has been detailed in the following contents. Rs1 and Rs2: Parasitic primary and secondary coil resistance Ls1 and Ls2: Primary and secondary coil inductance C1 and C2: Primary and secondary tank capacitors Zeq: the equivalent impedance of the secondary reflected to the primary Req: Zeq that has become real at the phase resonance frequency (ωresp) of the secondary tank

Task 1